What is the difference between direct circulation drilling and reverse circulation drilling?

user-image
Question ajoutée par Mushtaq Hussain Mushtaq , Senior Lab Supervisor , Al Mumayaz Laboratory
Date de publication: 2017/07/17
Amr Gouda
par Amr Gouda , Drilling Supervisor , Saudi Aramco

Direct circulation (Also known as normal circulation) is to pump drilling fluids into the drill string or tubing and get return from the annulus.

 

Reverse Circulation is to pump drilling fluids into the annulus and get return from the drill string or the tubing.

 PUMP THROUGH DRIL PIPE IS DIRECT CIRCULATION.                                              PUMP TROUGH ANNULUS  IS REVERSE CIRCULATION

Elhadi Bendifallah
par Elhadi Bendifallah , workover supervisor , Sinopec/Sonatrach

direct circulating means  throw inside drilling string  and reverse means thrw annular we have returm mud by inside string.als the difference is ls

presure