Trending Differential Equations Discussions

Follow

Ask the Community


Ask any professional question and get answers from other specialists.

Stream language
Himadri Roy's image
Question added by Himadri Roy MANAGER ELECTRICAL STEAG ENERGY SERVICES
7 years ago
Answers:
3
Followers:
Views:
849
Vote Count:
1
Answer should contain a minimum of 25 characters.
PAPPU MAJUMDER's image
Question added by PAPPU MAJUMDER Microsoft Business intelligence (MSBI) Equifax
8 years ago
Answers:
4
Followers:
Views:
1473
Vote Count:
2
Answer should contain a minimum of 25 characters.
majid ali's image
Question added by majid ali sinor chef engineer وزارة الكهرباء العراقية
10 years ago
Answers:
6
Followers:
Views:
16391
Vote Count:
1
Answer should contain a minimum of 25 characters.
Farhan Hayat's image
Question added by Farhan Hayat Site Engineer Malik Azam & Brothers
6 years ago
Answers:
0
Followers:
Views:
0
Vote Count:
0
Answer should contain a minimum of 25 characters.
Mobassar Hossain's image
Question added by Mobassar Hossain
7 years ago
Answers:
0
Followers:
Views:
28
Vote Count:
0
Answer should contain a minimum of 25 characters.
Default profile image
Question added by Janavi Sree
5 years ago
Answers:
0
Followers:
Views:
0
Vote Count:
0
Answer should contain a minimum of 25 characters.
jaikumar.g gopalakrishnan.a's image  
Answer added by  jaikumar.g gopalakrishnan.a, Project Associate, Central Power Research Institute
8 years ago

High impedance: In the High impedance differential relay the simple current or voltage based operated relay can be use as High impedance with the series of stabilizing re ... See More

Default profile image  
Answer added by  Essam Abouroash , Maintenance and Operation site Manager , Abu Qafrh Ready Mix Holding
5 years ago

The principle of differential busbar protection is very simple. Here, secondaries of CTs are connected parallel. That means, S1 terminals of all CTs connected together an ... See More

Mohamed El Hadad's image  
Answer added by  Mohamed El Hadad, Technical Project Manager, Electronic and Electrical Industries Corporation (EEIC)
10 years ago

In the High Impedenc DPR the Protection relay will have only one summation current input and it will pick up based on the difference in the current sumation. 

Nirmal Raja Periyalwar Linganna Jeyalalitha's image  
Answer added by  Nirmal Raja Periyalwar Linganna Jeyalalitha, SENIOR ELECTRICAL SITE ENGINEER, KCC Engineering & Contracting Company
6 years ago

The Relay which is used to protects the Bus Bar in the substation is called Bus Differential Relay. This relay acts on Differential current measurement principle. As per ... See More