What should be the maximum and minimum slump of concrete?

If on-site slump test fails, should engineers allow the contractor to continue the concreting works?

user-image
Question added by Hamza Muhammad Bakhsh , Quantity Surveyor , Engeering Kinetics (pvt) ltd.
Date Posted: 2018/01/15
Jalal Hussein Ali Musa Al'omari
by Jalal Hussein Ali Musa Al'omari , Civil Engineer , Local Office

In case of a dry sample, slump will be in the range of 25-50 mm. But in case of a wet concrete, the slump may vary from 150-175 mm. So the value of slump is specifically mentioned along the mix design and thus it should be checked as per local location.

Recommended slumps:

Reinforced foundation walls and footings:

a. Maximum Slump 75mm

b. Minimum Slump 25mm

 

Plain footings, caissons, and substructure walls:

a. Maximum Slump 75mm

b. Minimum Slump 25mm

 

Beams and reinforced walls:

a. Maximum Slump 100mm

b. Minimum Slump 25mm

 

Building columns:

a. Maximum Slump 100mm

b. Minimum Slump 25mm

 

Pavements and slabs:

a. Maximum Slump 75mm

b. Minimum Slump 25 mm

 

Mass Concrete Mix:

a. Maximum Slump 75mm

b. Minimum Slump 25mm

marvin montubig
by marvin montubig , crane opeator/driver , prolog cons.

maximum 125cm minimum 75cm

Babar Shahzad
by Babar Shahzad , Quantity Surveyor , CCECC

maximum 100cm minimum 75cm

Hadir Youssef
by Hadir Youssef , مهندسه مكتب فني , الفتح للانشاءات المعدنية

It varies  from country to country  and also depends on the type of the of buildings

 

sleem  orabi
by sleem orabi , Site Project Manager , Sarayya construction company

 you should follow the condition of your country 

Youssry  Maatouk
by Youssry Maatouk , HUMAN RESOURCE SPECIALIST , Abu Shaibah Group of Companies & Est.

a. Maximum Slump 75mm

b. Minimum Slump 25mm

 

shahid mahmood ali muhammad
by shahid mahmood ali muhammad , QC engineer , Saudi consulting services (saud consult)

gernal concrete slump 75 cm +-25 cm with out pump concrete if add chemical then depend on concrete desgine

Ahmed ElSayed Ali Ahmed Abdulaliem
by Ahmed ElSayed Ali Ahmed Abdulaliem , QS Engineer , Al-Joudah For Contracting

for all structure elements : maximum 75mm and minimum 25mm

but beams,columns and walls : maximum 100mm and minimum 25mm

Mahendra Pratap
by Mahendra Pratap , Supervisor , Stencil Engg. Pvt. Ltd

 If it's consolidated any other way, the slump should be 5 inches or less. 

Saddam husain Siddique
by Saddam husain Siddique , Quantity Surveyor , sasintl

100 + & - 25

max 125 mm

min 75 mm