Start networking and exchanging professional insights

Register now or log in to join your professional community.

Follow

How can we build a foundation for a column which subjected to tension?

In steel buildings some columns are subjected to tension.Which results in pull of the foundation.How this could be designed in a practical view point

user-image
Question added by SAMIH ABBAS KOTTACKAL , STRUCTURAL ENGINEER TRAINEE , CASE STRUCTURAL ENGINEERS
Date Posted: 2017/06/25
Salah  Uddin
by Salah Uddin , Research Assistant , Earthquake Center, University of Engineering and Technology Peshawar

In design consideration of foundation under column subjected to tension must be provided with sufficient embedded depth to have a higher pull out capacity. The skin friction (in piles) and/or weigth of soil above the footing will be contirbutive factors to the pull out capacity. The RC footing must then be designed for the load imposed by the column under tension, by providing tension reinforcement at the top of the footing block.

Ahmed Al Janubi
by Ahmed Al Janubi , Senior Civil/Structural Engineer , SNC-Lavalin Fayez Engineering

Consider your foundation as pinned connection to your steel column. Now, it is a matter of designing the anchorage for your column to take care of the tension. Make sure you have enough depth of your foundation for the embedment length of the anchor bolts to avoid the pullout.

FERNANDO JR SANOR
by FERNANDO JR SANOR , Independent Consulting Engineer , Norconsult Management Services Philippines, Inc

Run a Plaxis program/model in which you have to consider all the parameters related to structures above ground level and soil/rock parameters for the foundation.

Syed Mohammed Hussain Hussain
by Syed Mohammed Hussain Hussain , Senior Civil Structural Engineer , Worley Parsons Saudi Arabia

Provide top reinforcement in footing and increase the soil weight over top of footing.