Question added by SIMON JOSEPH XAVIER RAJ , Project Engineer , ABB Global Industries and Services Pvt. Limited
Date Posted: 2016/07/22
Muhammad Mwafy
by Muhammad Mwafy , Senior Design Engineer , Mabani Steel Buildings

It`s based on the code and the load case you check.If we are talking about the ECP. under the most severe load combination for portal frames (H/140)for multistory (H floor / 300) and (H building / 500)

SIMON JOSEPH XAVIER RAJ
by SIMON JOSEPH XAVIER RAJ , Project Engineer , ABB Global Industries and Services Pvt. Limited

ASCE 113 Manual had given a clear limitation about the deflection. It is height / 100 or height / 50 or height / 200 depends of usage of the strutural member. 