Bound and overheated 120v 3-phase motor has reversed direction of rotation. Direct drive 10-inch table saw. Can this be corrected?

user-image
Question added by Deleted user
Date Posted: 2015/08/23

SIMPLY SWAP THE NEGATIVE AND POSITIVE WIRES SUPPLYING POWER TO THE MOTOR

change one phase to change direction. before you commission a motor you test the phases like for3 seconds. if going opposite direction change the  2 phases.