If we doing concrete of a pier height 6m. what is the reason if honeycombing occur?

user-image
Question added by asif Iqbal , Site manager , Arial Construction & Industrial Company Ltd
Date Posted: 2017/01/24
Ammar BENNINI
by Ammar BENNINI , QC Coordinator , Consolidated Contractors International Company

 

 

It is the fall of the concrete which will provoke the segregation of the components, so it is preferable to take precautions for this type of activity, for example to provide an addition hose in such  way to decrease the height of the fall (should not exceed 1.5 m) , also to ensuring  the waterproof of the  formwork to avoid the loss of laitance .

Belal Hassan
by Belal Hassan , QA/QC Manager , ALGHANIM INTERNATIONAL GENERAL TRADING AND CONTRACTING CO.W.L.L

- Concrete Consolidation 

- Pouring Concrete height, not more than 1.3

- Poor Concrete Workability due to improper W/C Ratio

- Over size Aggregate

-   

PRABHASH KUMAR
by PRABHASH KUMAR , Structural Design Engineer , TULSI ENGINEERING CONSULTANCY HOUSE

- Concrete Consolidation

- Concrete Bleeding.

- Concrete Setting Time.

Mushtaq Hussain Mushtaq
by Mushtaq Hussain Mushtaq , Senior Lab Supervisor , Al Mumayaz Laboratory

Honey Combing is due to non-reaching of concrete to all places due to which cavities and hallow pockets are created. Main reasons for it are:-1. Improper vibration during concrete.2. Less covers to reinforcement bars.3. Use of very stif concrete.4. Places like junctions of beam to column and to one are more beams are typical spots where honey comb occurs.5. Presence of more percentage of larger size aggregates in concrete also prevent concrete to fill narrow spaces between bars.

JEASPIN SAM
by JEASPIN SAM , Sr. Business Development Executive , AL Sakhoor Trading and security services

Honeycombs are hollow spaces and cavities left in concrete mass on surface or inside the concretemass ... Honeycomb is due to non-reaching of concrete to all places due to which cavities and hallow pockets are created, main reasons are:.