What is the equation used to drainage design(under gravity pipe) and what is the minimum slope we can use?

user-image
Question added by Mohamed Shahawy , Senior Mechanical Engineer , Ebtekar al Memar For Trading
Date Posted: 2016/01/10

3% + V>2-2,5m/s according to the severity of the fractions in the water

 

lazhar boubendir
by lazhar boubendir , رصاص , zizou

V = (1.49/n)(Rh2/3)(S1/2),