Start networking and exchanging professional insights

Register now or log in to join your professional community.

Follow

Percentage of Steel and Concrete

user-image
Question added by Mohammed Gomaa , Senior Mobile Developer , Smart Dubai Government
Date Posted: 2015/04/07
Rimon Bestawrous
by Rimon Bestawrous , Site Manager , Nicheliving Pty.

Minimum reinforcementThe mild steel reinforcement in either direction in slabsshall not be less than0.15 percent of the total crosssectionalarea. However, this value can be reduced to0.12 percent when high strength deformed bars orwelded wire fabric are used.Longitudinal reinforcementThe cross-sectional area of longitudinalreinforcement, shall be not less than0.8 percentnor more than6 percent of the gross crosssectionalarea of the column.NOTE - The use of6 percent reinforcement may involvepractical difficulties in placing and compacting of concrete;hence lower percentage is recommended. Where bars fromthe columns below have to be lapped with those in thecolumn under consideration, the percentage of steel shallusually not exceed4 percent. 

More Questions Like This