DOES FREQUENCY IN SYNCHRONIZED POWER PLANT EFFECT THERMAL EXPANSION OF STEAM TURBINE ROTOR AND BODY??

user-image
Question added by MUHAMMAD MUNAM SALEEM RANA , ASSISTANT EXECUTIVE ENGINEER , PAKISTAN STEELMILLS KARACHI PAKISTAN(LARGEST INDUSTRY OF PAKISTAN)
Date Posted: 2015/03/05
Muhammad Shahzad Meo
by Muhammad Shahzad Meo , Senior Powwer Plant Operator , Fauji Fertilizer Bin Qasim Limited Karachi

when natural and forced frequency become equal,,,then critical speed achieved. it will cause by some imbalance of rotor.

now the frequency according to your question.

When frequency of turbine(forced frequency) equal to natural frequency of turbine(frequency of atoms of metal by which turbine is made of) become equal imbalance of rotor occur (if turbine rotate on this rpm for a while). vibration of turbine on critical speed increases...which ultiamtely effect on thermal expansion of turbine rotor and body(joins,nut,bolts) 