What is the minimum thickness for blind flange 8 inch for test pressure 200 bar?

user-image
تم إضافة السؤال من قبل مستخدم محذوف‎
تاريخ النشر: 2013/10/08

A pad that is4 inches think covers80ish sq ft per yard, so8 inch would be40ish sq ft per yard of concrete.

 

 

40 psi for10 min.

Muhammad Umair Ali Kumbrani
من قبل Muhammad Umair Ali Kumbrani , Draftsman cum Project Coordinator , Rafhan Maize Products Company Ltd.

Well this kind of flange is not available in Market but it thickess should be42mm and Wight is36.075 Kg

Mohamed Nagy
من قبل Mohamed Nagy , Piping design lead engineer. , Enppi (Engineering for Petroleum and Process Industries)

As per ASME B16.5 (pipe flanges and flanged fittings) for200 bar and assuming test medium is water @ ambient Temperature you should use1500 rating blind flange with minimum wall thickness of  91.9 mm

mazhar iqbal
من قبل mazhar iqbal , Piping Engineer , Jeoong Poong Halla Construction LLC.

40 mm THK

Gigin Oommen
من قبل Gigin Oommen , Mechanical Project Engineer , SETE Energy Saudia Ltd.

 

For class300 flanges – NPS1/2 to24

ASME B16.5 –1996

The thickness of the blind shall be41.1 mm minimum and it weighs around37 kgs.

You may also refer to Trouvay & Cauvin chapter on flanges for further details.

Hope that helps!

 

Accourding to DIN1092-1:2007 the thickness for flange8" is82mm at250bar

Milomir Tanaskovic
من قبل Milomir Tanaskovic , Marketing and Procurament Manager , MB Fapromal, Lucani

For Blind flg,8" class200, min thickness is41.1mm

Rey Jumaquio
من قبل Rey Jumaquio , Mechanical/Welding Engineer , ROBI Spol.sr.o

The minimum thickness for blind flange8'' thick is15 mm.